Principles Details

Radar

VEGAPULS WL 61

Measuring range    
up to 15 m  

Process fitting

thread G1½
mounting strap
compression flanges from DN 80, 3"

Process temperature 

-40 … +80 °C

Process pressure

 -1 … +2 bar
 (-100 … +200 kPa)

Measuring precision  

   ±2 mm

VEGAPULS 61

Measuring range

up to 35 m  

Process fitting
thread G1½, 1½ NPT
mounting strap
compression flanges from DN 80, 3"

Process temperature
-40 … +80 °C

Process pressure
-1 … +3 bar
(-100 … +300 kPa)

Measuring precision
+/- 2 mm
SIL qualification
optionally up to SIL2

VEGAPULS 62

Measuring range

up to 35 m

Process fitting
thread from G1½, 1½ NPT
flanges from DN 50, 2"

Process temperature
-200 … +450 °C

Process pressure
-1 … +160 bar
(-100…+16000 kPa)

Measuring precision
+/- 2 mm
SIL qualification
optionally up to SIL2
   

Guided Wave Radar

VEGAFLEX 81

Version

exchangeable cable probe
(ø 2 mm, ø 4 mm)
exchangeable rod probe
(ø 8 mm)
coax probe
(ø 21.3, mm, ø 42 mm)


Measuring range

cable probe up to 75 m
rod probe up to 6 m
coax probe up to 6 m


Process fitting
thread from G¾, ¾ NPT
flanges from DN 25, 1"


Process temperature
-40 … +200 °C


Process pressure
-1 … +40 bar
(-100 … +4000 kPa)


Accuracy
+/- 2 mm

 VEGAFLEX 83

Version

cable probe (ø 4 mm)
rod probe (ø 8 mm)

Measuring range

cable probe up to 32 m
rod probe up to 4 m

Process fitting
flanges from DN 25, 1"
hygienic fittings


Process temperature
-40 … +150 °C

Process pressure
-1 … +16 bar
(-100 … +1600 kPa)

Accuracy
+/- 2 mm

VEGAFLEX 86

Version

exchangebale cable probe

(ø 2 mm, ø 4 mm)
exchangeable rod probe
(ø 16 mm)
coax probe
(ø 42 mm)

Measuring range

cable probe up to 75 m
rod probe up to 6 m
coax probe up to 6 m

Process fitting

thread from G1½ , 1½ NPT
flanges from DN 50, 2"

Process temperature

-196 … +450 °C

Process pressure

-1 … +400 bar
(-100 … +40000 kPa)

 

Accuracy

+/- 2 mm

Ultrasonic

VEGASON 61

Measuring range

in liquids: 0.25 … 5 m
in bulk solids: 0.25 … 2 m

Process fitting

thread G1½, 1½ NPT

Process temperature

-40 … +80 °C

Process pressure

-0,2 … +2 bar
(-20 … +200 kPa)

Accuracy

+/- 10 mm

SIL qualificationoptionally up to SIL2

VEGASON 62

Measuring range

in liquids: 0.4 … 8 m
in bulk solids: 0.4 … 3.5 m

Process fitting
thread G2, 2 NPT

Process temperature
-40 … +80 °C

Process pressure
-0,2 … +2 bar
(-20 … +200 kPa)

Accuracy
+/- 10 mm

SIL qualification
optionally up to SIL2

VEGASON 63

Measuring range

in liquids: 0.6 … 15 m
in bulk solids: 0.6 … 7 m

Process fitting
compression flange DN 100
mounting strap

Process temperature
-40 … +80 °C

Process pressure
-0,2 … +1 bar
(-20 … +100 kPa)

Accuracy
+/- 10 mm

SIL qualification
optionally up to SIL2

Capacitive

VEGACAL 62

Version

partly insulated rod
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT
flanges from DN 25, 1"Materialssteel, 316L, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)
SIL qualification
optionally up to SIL2

 

VEGACAL 63

Version

fully insulated rod


Measuring range
up to 6 m


Process fitting
thread from G¾, ¾ NPT
flanges from DN 25, 1"


Materials
316L, PE, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)


SIL qualification
optionally up to SIL2

VEGACAL 64

Version

fully insulated rod


Measuring range
up to 4 m


Process fitting
thread from G¾, ¾ NPT
flanges from DN 25, 1"
Materials
316L, FEP


Process temperature
-50 … +150 °C


Process pressure
-1 … +64 bar
(-100 … +6400 kPa)


SIL qualification
optionally up to SIL2

Hydrostatic

VEGABAR 66

Measuring cell

CERTEC


Sensor diameter
32 mm


Measuring range
0 … +25 bar (0 … +2500 kPa)


Process fitting
thread from G1½, 1½ NPT
flanges from DN 40, 2"


Process temperature
-40 … +100 °C
Deviation of characteritics
0.1 %


SIL qualification
optionally up to SIL2

VEGABAR 66

Measuring cell

METEC


Sensor diameter
40 mm


Measuring range
0 +25 bar (0 +2500 kPa)


Process fitting
thread from G1, 1 NPT
flanges from DN 50, 2"


Process temperature
-12 +100 C
Deviation in characteritics
0.1 %


SIL qualification
optionally up to SIL2

VEGAWELL 52

Measuring cell

CERTEC


Sensor diameter
from 22 mm


Measuring range
0 … +60 bar (0 … +6000 kPa)


Process temperature
-20 … +80 °C


Deviation in characteritics
0.2 %; 0.1 %

Radiation-based

FIBERTRAC 31

Version

sensor with flexible plastic detector ø 42 mm


Measuring range
up to 7 m


Mounting
from outside on the vessel


Reproducibility
± 0.5 %


SIL qualification
optionally up to SIL2

SOLITRAC 31

Version
sensor with PVT rod detector


Measuring range
up to 3 m


Mounting
from outside on the vessel


Reproducibility
± 0.5 %


SIL qualification
optionally up to SIL2